Hextio

VIRUSKILLER™ Kills Coronavirus in the Air*

VIRUSKILLER™ Kills Coronavirus in the Air*

Air quality is important to physical and mental wellbeing. It has become even more crucial as Coronavirus can be spread via the air to people. Reducing the risk of airborne transmission requires more than opening doors and windows or installing standard air filters which may not be effective against enveloped viruses. 

Our VIRUSKILLER™ Kills Coronavirus in the Air* and will help to increase the air quality of your building. Installing these units will help to stop airborne transmission of infectious illnesses, making these spaces safer for customers, visitors and staff.

*When independently tested against Coronavirus DF2 (a surrogate for Coronavirus), Adenovirus, Influenza and Polio, the unit was found to kill 99.9999% of viruses on a single air pass.

Book a Viruskiller now!

The VIRUSKILLER™ story

Efficient UV Air Filtration and Decontamination Technology

VIRUSKILLERTM achieves one of the most efficient virus deactivation rate as it goes through 2 stage process in purification and disinfection. Organic and biological contaminants are exposed to UV-C Reactor Chamber, where germicidal hydroxyl radicals are produced to deactivate viruses, bacteria, mould and fungi. Finally, clean air is then delivered back into the breathing zone, offering real-time indoor air protection.

Engineered infection control to remove and neutralise toxic air

Controlled airflow

Create a laminar airflow and replace with sterilised clean air in the breathing zone.

Single air pass technology

Deactivates viruses and bacteria with unequalled efficiency in a single air pass.

UV-C Decontamination

Air goes through a patented Reactor Camber to neutralise harmful pathogens.

Recommended locations to install the VIRUSKILLER™

Education

Improves attendance by reducing the risk of infections spreading.

Hospitality

Helps businesses to reopen safely by reducing airborne infections.

Office

Promotes a safe workplace by lowering airborne transmission.

VIRUSKILLER™ - Our Services

Rental

  • Product will be offered at a minimum contract period of 2 Years.

Contract includes:

  • Monthly maintenance of pre filter.
  • Replacement of Hepa and Activated carbon filter will be based on the usage hours.
  • Replacement of Reaction chamber will be based the usage hours.
  • Repair or replacement of defective parts during contract period.
  • Specialized and devoted service team.

Outright Buy-out

  • 1 year warranty. Product installation done by Initial Hygiene Team.
  • Initial Hygiene Technicians will provide inhouse training related to monthly cleaning / maintenance.
  • Charges will be incurred on additional on field guidance / support requested by customers.
  • Pre-Filters, Carbon Filter, HEPA filter, UVC lamp and/or repairs and maintenance of the unit incurred on additional cost.

Tested for Performance: Hextio, VK 401, VK 102, VK 103

Type of Test Test Laboratory                                          Test Brief Test Result
Mycobacterium tuberculosis, Klebsiella pneumoniae, Staphyloccus aureus, Streptoccocus pneumoniae & Streptococcus pyogenes

Gyeonggi Pharmaceutical Research Centre

(South Korea)

Tested against elimination of Bacteria. 99.9999%
Adenovirus, Coronavirus DF2 & Influenza

Gyeonggi Pharmaceutical Research Centre

(South Korea)

Tested against elimination of Viruses. 99.9999%

Safety Certificates

Type of Test Methods Certificate Authority                       Test Brief
IEC 62471:2019 Korean Institute of Lighting and ICT (South Korea) No UV-C Leakage: Hextio, VK 401, VK 102 & 103
IEC 60335-1:2010, IEC 60335-2-65:2002, IEC 60335-2-65:2002/AMD1:2008 CB Certification IEC system for manual recognition of test and certificates for electrical equipment (IECEE) CB Scheme
IEC 63000:2016, IEC 62321:2008,IEC 62321-1:2013, IEC 62321-2:2013, IEC 62321-3-1:2013, IEC 62321-3-2:2013, IEC 62321-4:2017, IEC 62321-5:2013, IEC 62321-6:2015, IEC 62321-7-1:2015, IEC 62321-7-2:2017, IEC 62321- 8:2017, IEC/TR 62476:2010, IEC TR 62474-1:2015

RoHS - Emirates Authority for standardization & Metrology (UAE)

Equipment Safety to Humans and Environment

EN 50581:2012 ; EN 62321:2009; IEC 62321-8:2017

Declaration of conformity according to RoHS directive 2011/65/EU (South Korea)

EN 50581:2012;  IEC 62321-1:2013;  IEC 62 321-3-1:2013;                        

EN 62321:2009; IEC 62321-8:2017

SNS EMC Laboratory Co. Ltd (South Korea)

Safety Regulations

Certificates                    Certificate Authority Result
FCC Suppliers Declaration of Conformity The Federal Communications Commission certifies that electromagnetic interference from VIRUSKILLER™ units is within the approved limits.
ISO IGC - Institute of Global Certification Management System Certification Body No . MSCB- 105 ISO 9001:2015 specifies requirements for a quality management system demonstrating company's ability to consistently provide products and services that meet customer and applicable statutory and regulatory requirements.

VIRUSKILLER TM VK 401 has been tested in India forthe following:

Sr.no Name of microorganism Type of Microorganisms
1 Staphylococcus aureus Gram positive cocci
2 Escherichia coli Gram negative rods
3 Pseudomonas aeruginosa Gram negative rods
4 Candida albican Yeast
5 Aspergillus niger Filamentous fungus
6 Phi X 174 ss DNA Virus
7 MS 2 ss RNA virus

Test reports are available upon request. Contact us

Locations


Contact


Call your local branch

Contact us on: 1800 266 2200  

or fill out your details and we will call you back